A proven advancement in RapidCycle™ sterilization, the RH-Pro11 sterilizer will raise your level of sterilization efficiency. Using Cutting-Edge HVHA (High-Velocity Hot Air)
technology, the RH-Pro11 provides the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no lengthy drying cycle with
longer instrument life free of corrosion.
For Healthcare, the RH-Pro11 can Eliminate “Immediate-Use” Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny. With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.
RH-Pro11 Installation and Operation Video
Features
With four (4) removable trays, the RH-Pro11 chamber can be easily modified to handle all sizes of instrument sets.
The RH-PRO11 Advantage
• FDA-Cleared 6 Minute Sterilization Cycles (Unwrapped)
• FDA-Cleared 12 Minute Sterilization Cycles (Wrapped)
• Large Table-Top Capacity (2295 Cubic Inches)
• Uses 65% Less Energy Than Steam
• Non-Corrosive Sterilizer Environment
• Full 3-Year Warranty
• Waterless Sterilization with No Chemicals
• Greater Capacity — Four Large Trays
Specifications
Unit Size (OD) | 21.5″ W x 22.5″ D x 19.5″ H 546.1 mm x 572 mm x 495 mm |
Chamber Size (ID) | 11”W x 17.75”D x 11.75”H, 279mm x 433mm x 299mm |
Weight | 91 lbs (41 Kg) |
Instrument Tray | 9”W x 15”D x 1”H, 229mm x 381mm x 28mm |
Electrical | 110-120V, 60Hz, 1400 Watts warm up, 300 Watts operating 220-240V, 60Hz, 1400 Watts warm up, 300 Watts operating |
Sterilization Temperature | 375°F (190°C) 320°F (160°C) 300°F (149°C) 280°F (138°C) |
Warranty | Three years (parts and labor) |
Safety | Meets Requirements of U.S. Electrical Safety Standards. |
Sterilization Cycle Times
Total Sterilization Processing Times 375°F
- Unwrapped Instruments – 14 Minutes
- Handpieces 16 Minutes
- Wrapped / Pouched Instruments – 21 Minutes
- Wrapped Cassettes 40 Minutes
Total Sterilization Processing Time Low-Temperature
- 320°F – 42 Minutes
- 300°F – 58 Minutes
- 280°F – 126 Minutes
The RapidHeat RH-Pro Advantage
No Dry Cycle
Improves Instrument Turnaround Time and removes the threat of environmental contamination and instrument corrosion from wet instruments.
No Water
Saves Time & Improves Patient Safety – With no water required, the potential for contamination from improperly cleaned water reservoirs is eliminated.
No Extensive Maintenance
There is no costly and time-consuming maintenance – Only a few minutes a week is needed to ensure the safe and effective operation of an RH-Pro Sterilizer.